Abstract
Abstract:Isopropyl alcohol is a relatively common source of clinical intoxication. It is usually suspected when a patient presents with high serum or urine ketones and a high osmolar gap without acidosis. Acute renal failure due to isopropyl alcohol ingestion is rare. We describe a patient with isopropyl alcohol ingestion who presented with renal failure, but with a false elevation of serum creatinine secondary to interference by acetone with the colorimetric assay for creatinine. We highlight the use of blood gas analyzers, which use an enzymatic assay, thus avoiding acetone interference, as a quick method to correctly estimate the serum creatinine concentration and avoid labeling the patient as having acute renal failure.
This content is limited to qualifying members.
If you have an existing account please login now to access this article or view purchase options.
Create a free account, then purchase this article to download or access it online for 24 hours.
Create a free account, then purchase a subscription to get complete access to all articles for a full year.
References
References1. Zaman F, Pervez A, Abreo K. Isopropyl alcohol intoxication: a diagnostic challenge. Am J Kidney Dis 2002;40:E12.ZamanF]]PervezA]]AbreoKIsopropyl alcohol intoxication: a diagnostic challenge.Am J Kidney Dis200240E122. Abramson S, Singh AK. Treatment of the alcohol intoxications: ethylene glycol, methanol and isopropanol. Curr Opin Nephrol Hypertens 2000;9:695–701.AbramsonS]]SinghAKTreatment of the alcohol intoxications: ethylene glycol, methanol and isopropanol.Curr Opin Nephrol Hypertens20009695-7013. White S. The poisoned patient with metabolic acidosis (a medical toxicologist's perspective). Midwest Assoc Toxicol Ther Drug Monit Newsl 2002;8:1.WhiteSThe poisoned patient with metabolic acidosis (a medical toxicologist's perspective).Midwest Assoc Toxicol Ther Drug Monit Newsl2002814. Lacoutre PG, Heldreth DD, Shannon M, et al. The generation of acetonemia/acetonuria following ingestion of a subtoxic dose of isopropyl alcohol. Am J Emerg Med 1989;7:38–40.LacoutrePG]]HeldrethDD]]ShannonM&etal;The generation of acetonemia/acetonuria following ingestion of a subtoxic dose of isopropyl alcohol.Am J Emerg Med1989738-405. Hawley PC, Falko JM. “Pseudo” renal failure after isopropyl alcohol intoxication. South Med J 1982;75:630–631.HawleyPC]]FalkoJM“Pseudo” renal failure after isopropyl alcohol intoxication.South Med J198275630-6316. Peng LW, Janga R, Lien YH. Isopropyl alcohol-induced pseudo-azotemia: taking advantage of a laboratory error. Am J Med 2006;119:e9.PengLW]]JangaR]]LienYHIsopropyl alcohol-induced pseudo-azotemia: taking advantage of a laboratory error.Am J Med2006119e97. Wakins PJ. The effect of ketone bodies on the determination of creatinine. Clin Chim Acta 1967;18:191–196.WakinsPJThe effect of ketone bodies on the determination of creatinine.Clin Chim Acta196718191-1968. Haugen HN. Glucose and acetone as sources of error in plasma creatinine determinations. Scand J Clin Lab Invest 1954;6:17–21.HaugenHNGlucose and acetone as sources of error in plasma creatinine determinations.Scand J Clin Lab Invest1954617-219. Gabrielli A, Hammett-Stabler C. False elevation of serum creatinine following skin absorption of nitromethane complicates the clinical diagnosis of rhabdomyolysis. Chest 1998;113:1419–1422.GabrielliA]]Hammett-StablerCFalse elevation of serum creatinine following skin absorption of nitromethane complicates the clinical diagnosis of rhabdomyolysis.Chest19981131419-142210. Peake M, Whiting M. Measurement of serum creatinine—current status and future goals. Clin Biochem Rev 2006;27:173–184.PeakeM]]WhitingMMeasurement of serum creatinine—current status and future goals.Clin Biochem Rev200627173-18411. Flegar-Mestrić Z, Perkov S. Comparibilty of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Xpress analyzer and standard laboratory methods. Clin Chem Lab Med 2006;44:898–903.Flegar-MestrićZ]]PerkovSComparibilty of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Xpress analyzer and standard laboratory methods.Clin Chem Lab Med200644898-903