Original Article

Measurement of Central Venous Pressure from a Peripheral Intravenous Catheter in the Prone Position During Spinal Surgery

Authors: Joseph D. Tobias MD

Abstract

Introduction:A central venous pressure (CVP) measurement is used to assess intravascular status. Although this is usually accomplished by the placement of a central venous catheter (CVC), there are circumstances when placement may be technically difficult or impossible. The current study evaluates the feasibility of measuring CVP from a peripheral intravenous (IV) cannula in the prone position.Methods:CVP was simultaneously measured from a central venous catheter (CVC-P) and from a peripheral IV cannula (PVP). The continuity of the peripheral IV cannula with the central venous system was demonstrated by a change in the PVP during a sustained inspiratory effort.Results:The study cohort included 18 patients. All patients had 2 peripheral IV cannulae, and 10 PVP measurements were taken from each site. In 4 of the 36 cannulae (11%), there was no increase in the PVP in response to a sustained inspiratory effort. For these 4 cannulae, the PVP to CVC-P difference was 13 ± 4 mm Hg. In the 32 cannulae in which the PVP increased in response to a sustained inspiratory effort, the PVP to CVC-P difference was 2 ± 1 mm Hg (P < 0.0001), and the difference between the PVP and the CVC-P was ≤5 mm Hg in all of the sample sets. The accuracy of the technique did not vary based on the location of the peripheral cannula, its size, or the actual CVP reading.Conclusion:Provided that the PVP increases to a sustained inspiratory breath, there is a clinically useful correlation between the PVP and the actual CVP in the prone position.

This content is limited to qualifying members.

Existing members, please login first

If you have an existing account please login now to access this article or view purchase options.

Purchase only this article ($25)

Create a free account, then purchase this article to download or access it online for 24 hours.

Purchase an SMJ online subscription ($75)

Create a free account, then purchase a subscription to get complete access to all articles for a full year.

Purchase a membership plan (fees vary)

Premium members can access all articles plus recieve many more benefits. View all membership plans and benefit packages.

References

References1. Sznajder JI, Zveibil FR, Bitterman H, et al. Central vein catheterization. Failure and complication rates by three percutaneous approaches. Arch Intern Med 1986;146:259–261.SznajderJI]]ZveibilFR]]BittermanH&etal;Central vein catheterization. Failure and complication rates by three percutaneous approaches.Arch Intern Med1986146259-2612. Domino KB, Bowdle TA, Posner KL, et al. Injuries and liability related to central vascular catheters: a closed claims analysis. Anesthesiology 2004;100:1411–1418.DominoKB]]BowdleTA]]PosnerKL&etal;Injuries and liability related to central vascular catheters: a closed claims analysis.Anesthesiology20041001411-14183. Winsor T, Burgh GE. Use of the phlebomanometer: normal venous pressure values and a study of certain clinical aspects of venous hypertension. Am Heart J 1946;31:387–406.WinsorT]]BurghGEUse of the phlebomanometer: normal venous pressure values and a study of certain clinical aspects of venous hypertension.Am Heart J194631387-4064. Amar D, Melendez JA, Zhang H, et al. Correlation of peripheral venous pressure and central venous pressure in surgical patients. J Cardiothor Vasc Anesth 2001;15:40–43.AmarD]]MelendezJA]]ZhangH&etal;Correlation of peripheral venous pressure and central venous pressure in surgical patients.J Cardiothor Vasc Anesth20011540-435. Munis JR, Bhatia S, Lozada LJ. Peripheral venous pressure as a hemodynamic variable in neurosurgical patients. Anesth Analg 2001;92:172–179.MunisJR]]BhatiaS]]LozadaLJPeripheral venous pressure as a hemodynamic variable in neurosurgical patients.Anesth Analg200192172-1796. Parker JL, Flucker CJ, Harvey N, et al. Comparison of external jugular and central venous pressures in mechanically ventilated patients. Anaesthesia 2002;57:596–600.ParkerJL]]FluckerCJ]]HarveyN&etal;Comparison of external jugular and central venous pressures in mechanically ventilated patients.Anaesthesia200257596-6007. Desjardins R, Denault AY, Bélisle S, et al. Can peripheral venous pressure be interchangeable with central venous pressure in patients undergoing cardiac surgery? Intensive Care Med 2003;30:627–632.DesjardinsR]]DenaultAY]]BélisleS&etal;Can peripheral venous pressure be interchangeable with central venous pressure in patients undergoing cardiac surgery?Intensive Care Med200330627-6328. Cox P, Johnson JO, Tobias JD. Measurement of central venous pressure from a peripheral intravenous catheter in the lower extremity. South Med J 2005;98:698–702.CoxP]]JohnsonJO]]TobiasJDMeasurement of central venous pressure from a peripheral intravenous catheter in the lower extremity.South Med J200598698-7029. Tobias JD, Johnson JO. Measurement of central venous pressure from a peripheral vein in infants and children. Pediatr Emerg Care 2003;19:428–430.TobiasJD]]JohnsonJOMeasurement of central venous pressure from a peripheral vein in infants and children.Pediatr Emerg Care200319428-43010. Milhoan KA, Levy DJ, Shields N, et al. Upper extremity peripheral venous pressure measurements accurately reflect pulmonary artery pressures in patients with cavopulmonary or Fontan connections. Pediatr Cardiol 2004;25:17–19.MilhoanKA]]LevyDJ]]ShieldsN&etal;Upper extremity peripheral venous pressure measurements accurately reflect pulmonary artery pressures in patients with cavopulmonary or Fontan connections.Pediatr Cardiol20042517-1911. Anter AM, Bondok RS. Peripheral venous pressure is an alternative to central venous pressure in paediatric surgery patients. Acta Anaesthesiol Scand 2004;48:1101–1104.AnterAM]]BondokRSPeripheral venous pressure is an alternative to central venous pressure in paediatric surgery patients.Acta Anaesthesiol Scand2004481101-110412. Baty L, Russo P, Tobias JD. Measurement of central venous pressure from a peripheral intravenous catheter following cardiopulmonary bypass in infants and children with congenital heart disease. J Intensive Care Med 2008;23:136–142.BatyL]]RussoP]]TobiasJDMeasurement of central venous pressure from a peripheral intravenous catheter following cardiopulmonary bypass in infants and children with congenital heart disease.J Intensive Care Med200823136-142