Case Report

Near-fatal Air Embolism: Fibrin Sheath as the Portal of Air Entry

Authors: Shawn Roberts, MD, Michelle Johnson, MD, Scott Davies, MD

Abstract

Complications of central venous catheters occur in less than 1% of all insertions. Of these, pulmonary air embolism is a rare though often fatal complication. Possible mechanisms include opening of the line to the atmosphere during use and poor technique during insertion or removal. There has also been speculation that the presence of a fibrin sheath after removal might be a mechanism for air entry. We present a case of a near-fatal pulmonary air embolus with documentation of air in the pulmonary outflow trunk and a residual air-filled fibrin tract seen on computed tomography.

This content is limited to qualifying members.

Existing members, please login first

If you have an existing account please login now to access this article or view purchase options.

Purchase only this article ($25)

Create a free account, then purchase this article to download or access it online for 24 hours.

Purchase an SMJ online subscription ($75)

Create a free account, then purchase a subscription to get complete access to all articles for a full year.

Purchase a membership plan (fees vary)

Premium members can access all articles plus recieve many more benefits. View all membership plans and benefit packages.

References

1. Kashuk J, Penn I. Air embolism after central venous catheterization. Surg Gynecol Obstet 1984; 159: 249–252.
 
2. Hoshal V, Ause R, Hoskins P. Fibrin sleeve formation on indwelling subclavian central venous catheters. Arch Surg 1971; 102: 353–358.
 
3. Boer W, Hene R. Lethal air embolism following removal of a double lumen jugular vein catheter. Nephrol Dial Transplant 1999; 14: 1850–1852.
 
4. Hanley P, Click R, Tancredi R. Delayed air embolism after removal of venous catheters. Ann Intern Med 1984; 101: 401–402.
 
5. Turnage S, Harper J. Venous air embolism occurring after removal of a central venous catheter. Anesth Analg 1991; 72: 559–560.
 
6. Madden B, Paruchuru P, Kunst H. Sucking noise and collapse after central venous catheter removal. J R Soc Med 2000; 93: 592–593.
 
7. Phifer T, Bridges M, Conrad S. The residual central venous catheter track: An occult source of lethal air embolism—Case report. J Trauma 1991; 31: 1558–1560.
 
8. McCarthy PM, Wang N, Birchfield F, Mehta AC. Air embolism in single-lung transplant patients after central venous catheter removal. Chest 1995; 107: 1178–1179.
 
9. Mennim P, Coyle C, Taylor J. Venous air embolism associated with removal of central venous catheter. BMJ 1992; 305: 171–172.
 
10. Sing RF, Thomason MH, Heniford BT, Miles WS, Huynh TT, Jacobs DG, et al. Venous air embolism from central venous catheterization: Under-recognized or over-diagnosed? Crit Care Med 2000; 28: 3377–3378 (letter).
 
11. Ely EW, Hite RD, Baker AM, Johnson MM, Bowton DL, Haponik EF. Venous air embolism from central venous catheterization: A need for increased physician awareness. Crit Care Med 1999; 27: 2113–2117.
 
12. Dumont C. Procedures nurses use to remove central venous catheters and complications they observe: A pilot study. Am J Crit Care 2001; 10: 151–155.